{"product_id":"qp2320-q-page-bis-tris-precast-gel-mini-15-wells-12-10-gels","title":"Q-PAGE™ Bis-Tris Precast Gel (Mini, 15 Wells, 12%), 10 Gels","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ-PAGE™ Bis-Tris Precast Gel – Mini, 15 Wells, 12%, 10 Gels\u003c\/strong\u003e is a ready-to-use polyacrylamide gel system from SMOBIO Technology for high-resolution protein separation by SDS-PAGE using the Bis-Tris buffer system.\u003c\/p\u003e\n\u003cp\u003eThe optimized Bis-Tris formulation provides clear, sharp protein bands, improved resolution and extended storage stability compared with conventional manually prepared Laemmli Tris-HCl gels. Its ready-to-use format eliminates gel casting and supports consistent performance between electrophoresis runs.\u003c\/p\u003e\n\u003cp\u003eThe gel contains a fixed 12% polyacrylamide concentration, providing a uniform resolving matrix with consistent pore size. It is particularly suitable for routine separation of small- to medium-sized proteins and for applications where the proteins of interest fall within a relatively defined molecular-weight range.\u003c\/p\u003e\n\u003cp\u003eThe running buffer can be selected according to the desired separation range. MES-SDS buffer is generally preferred for smaller proteins and faster migration, while MOPS-SDS buffer may be used when greater resolution of medium-sized proteins is required.\u003c\/p\u003e\n\u003cp\u003eThe Mini cassette measures 10 × 8.3 cm and contains a gel measuring 8.1 × 7.4 × 0.1 cm. Each gel contains 15 numbered and framed wells with a maximum recommended loading capacity of 22 µL per well. This configuration supports increased sample throughput within a compact Mini cassette.\u003c\/p\u003e\n\u003cp\u003eQ-PAGE™ Bis-Tris Mini gels are designed primarily for Bio-Rad® Mini-PROTEAN® systems and other electrophoresis tanks compatible with the same Mini cassette dimensions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e Ready-to-use Bis-Tris precast gels • Fixed 12% polyacrylamide concentration • Suitable for small- to medium-sized proteins • Compact Mini cassette format • Clear and sharp protein bands • High resolution • 15 numbered and framed wells • 22 µL maximum capacity per well • Compatible with MOPS-SDS and MES-SDS running buffers • Compatible with Bio-Rad® and similar Mini systems • Suitable for protein staining and Western blotting • Stable for ambient-temperature transportation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Bis-Tris SDS-PAGE • Small- and Medium-Size Protein Separation • Routine Protein Analysis • Protein Molecular-Weight Estimation • Protein-Purity Assessment • Recombinant Protein Analysis • Protein Expression Studies • Gel Staining • Western Blot Sample Separation • General Proteomics Research\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Running Buffers:\u003c\/strong\u003e MES-SDS for smaller proteins and faster migration • MOPS-SDS for medium-sized proteins. SMOBIO SMOChem™ 1X MOPS-SDS Running Buffer Powder, Cat. No. BF2000, is compatible with this gel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Electrophoresis Systems:\u003c\/strong\u003e Bio-Rad® Mini-PROTEAN® systems • Other electrophoresis systems compatible with 10 × 8.3 cm Mini gel cassettes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents:\u003c\/strong\u003e 10 Q-PAGE™ Bis-Tris Mini precast gels • Product-description tip card • Gel remover • Cassette opener\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e Store the gels flat at 4°C for up to 12 months. Do not freeze. Keep the gels in their original packaging until required for use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHandling:\u003c\/strong\u003e Remove the cassette sealing tape and comb before electrophoresis. Rinse the wells with compatible running buffer, fill the wells with running buffer and then load the prepared samples and protein marker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Compatibility Note:\u003c\/strong\u003e Do not use Tris-Glycine running buffer with Q-PAGE™ Bis-Tris Precast Gels. An incompatible running buffer can cause abnormal protein migration and poor resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Use:\u003c\/strong\u003e Research Use Only (RUO). Not intended for diagnostic or clinical use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e SMOBIO Technology, Inc.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 22px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; line-height: 1.4;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #d9d9d9; background: #f5f5f5; padding: 9px 10px; text-align: left; width: 42%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #d9d9d9; background: #f5f5f5; padding: 9px 10px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eCatalogue No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eQP2320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e10 precast gels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eQ-PAGE™ Bis-Tris Precast Gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eGel Chemistry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eBis-Tris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eElectrophoresis Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eDenaturing SDS-PAGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eGel Percentage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e12% polyacrylamide, fixed concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eRecommended Protein Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eSmall- to medium-molecular-weight proteins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eCompatible Buffer Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eMOPS-SDS and MES-SDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eMOPS-SDS Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eSeparation of medium-sized proteins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eMES-SDS Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eSeparation of smaller proteins and faster migration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eCassette Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eMini gel cassette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eCassette Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e10 × 8.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eGel Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e8.1 × 7.4 × 0.1 cm (width × length × thickness)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eGel Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eNumber of Wells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eMaximum Well Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e22 µL per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eWell Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eNumbered and framed wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eBio-Rad® Mini-PROTEAN® and compatible Mini electrophoresis systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003ePrimary Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eClear, sharp bands and high-resolution protein separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eDownstream Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eProtein staining, imaging and Western blot transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eAccessories Supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eProduct-description tip card, gel remover and cassette opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eTransportation Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eStable for shipping at ambient temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e4°C; store flat and do not freeze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eStated Shelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eUp to 12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003e\u003cstrong\u003eClassification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 8px 10px;\"\u003eResearch Use Only (RUO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666;\"\u003e\u003cem\u003eImportant: Q-PAGE™ Bis-Tris gels require a compatible MOPS-SDS or MES-SDS running buffer. Do not use the BF4000 Tris-Glycine-SDS buffer intended for Q-PAGE™ TGN gels.\u003c\/em\u003e\u003c\/p\u003e","brand":"SMOBIO","offers":[{"title":"Mini 15 wells 12%","offer_id":64347132330361,"sku":"QP2320","price":295.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0945\/3043\/7497\/files\/QP2320_QP2320_Q-PAGE_Bis-TrisPrecastGel_Mini_15wells_12_10gels.png?v=1787489529","url":"https:\/\/hayubiomedical.co.uk\/products\/qp2320-q-page-bis-tris-precast-gel-mini-15-wells-12-10-gels","provider":"HAYU Biomedical Limited","version":"1.0","type":"link"}