Prepared slides
For teaching and research observations of cells, tissue sections and suitable microorganisms. Specimen preparation affects the detail you can observe.
PRODUCT INFORMATION
UK/EU ordering: add this item to cart, review your order, then continue securely to checkout.
PRODUCT INFORMATION
iScope binocular microscope with EWF 10x/22 mm eyepieces, plan phase PLPHi 10/20/S40/S100x oil IOS objectives, Zernike phase contrast disc condenser with darkfield stop, rackless stage and Köhler 3 W NeoLED illumination.
Use thin, suitably prepared specimens for transmitted-light observation. Match the objective, condenser setting and contrast technique to your specimen. This configuration is selected by its exact catalogue number.
For teaching and research observations of cells, tissue sections and suitable microorganisms. Specimen preparation affects the detail you can observe.
Read the supplied objectives and eyepiece specification below. Total magnification is eyepiece magnification multiplied by objective magnification.
A camera requires a compatible optical port and adapter unless an integrated camera is explicitly listed. Binocular and trinocular heads have different camera options.
EWF 10x/22 mm eyepieces
The eyepiece magnification combines with the objective. Field number helps compare the visible area when the optical setup is otherwise equivalent.
Binocular version with Siedentopf 30° inclined tubes. Interpupillary distance 48-76 mm with diopter adjustment on both eyepieces
Viewing heads affect how you use the instrument and whether a dedicated camera port is available. A camera and adapter may need to be purchased separately.
187/230 x 140 mm rackless stage equipped with integrated 79 x 52 mm mechanical stage
Stage size determines the space for the specimen. Mechanical travel determines how far you can scan without repositioning the slide.
Coaxial coarse and fine adjustments with 200 graduations. Precision 1 μm, 0.2 mm per rotation. Total travel approximately 24 mmRack-stop for protection of slides and objectives. Friction adjustment
Fine focus helps resolve small changes in specimen height at higher magnification. Use the focusing controls and travel limits according to the manual.
Height adjustable Zernike rotating N.A. 1.25 condenser with phase annuli and darkfield stop
The condenser shapes the illumination at the specimen. Its iris needs adjustment for the selected objective and observation technique.
Diascopic intensity adjustable 3 W NeoLED Köhler illumination with Internal 100-240 V power supply (CE)iCare Sensor: The illumination of the microscope automatically switches off when the microscopist steps away from his position, saving energyCSS - Cable Storage System. The Cable Storage System of the iScope allows the user to easily insert the power cable into the back of the instrument, which enables easy storage
Check both the illumination method and its power requirements. Adjust brightness for the sample and viewing conditions.







HAYU learning illustration. It explains the workflow and is not a drawing of the supplied equipment.
| Model number | IS.1152-PLPHi |
|---|---|
| Series | iScope · Education biological microscopes |
| Level | Professional |
| Eyepieces | EWF 10x/22 mm eyepieces |
| Head | Binocular version with Siedentopf 30° inclined tubes. Interpupillary distance 48-76 mm with diopter adjustment on both eyepieces |
| Nosepiece | Revolving quintuple reversed nosepiece on ball bearings plan phase PLPHi 10x/0.25, 20x/0.40, S40x/0.65, S100x/1.25 oil immersion IOS objectives |
| Optics | All optics are anti-fungus treated and anti-reflection coated for maximum light throughput |
| Stage | 187/230 x 140 mm rackless stage equipped with integrated 79 x 52 mm mechanical stage |
| Focusing | Coaxial coarse and fine adjustments with 200 graduations. Precision 1 μm, 0.2 mm per rotation. Total travel approximately 24 mmRack-stop for protection of slides and objectives. Friction adjustment |
| Condenser | Height adjustable Zernike rotating N.A. 1.25 condenser with phase annuli and darkfield stop |
| Illumination & power | Diascopic intensity adjustable 3 W NeoLED Köhler illumination with Internal 100-240 V power supply (CE)iCare Sensor: The illumination of the microscope automatically switches off when the microscopist steps away from his position, saving energyCSS - Cable Storage System. The Cable Storage System of the iScope allows the user to easily insert the power cable into the back of the instrument, which enables easy storage |
Model specifications are taken from the supplied Euromex catalogue and linked manufacturer resources. Configurations can vary by catalogue number. HAYU can confirm current supplied components before ordering.
Videos load only after you select Play. Hosted by Vimeo.
Manufacturer tutorial for the named series or configuration. Match the supplied components to the specification above.
Open video separatelyGeneral training video. It may show different equipment.
Open video separatelyGeneral training video. It may show different equipment.
Open video separatelySupplied with power cord, 500 mA 250 V spare fuse, 5 ml immersion oil, dust cover, alignment telescope and green filter in styrofoam case
Additional cameras, stands, adapters and accessories are included only when named in this product’s supplied configuration.
Listed by the manufacturer for this series. Compatibility can depend on optical configuration, head or stand. Confirm the fit for IS.1152-PLPHi before ordering.
Tell HAYU Biomedical about your sample, required observation or measurement, and existing equipment. Include this catalogue number so we can check the configuration and compatible accessories.
Ask about this productResearch and education use only. Not intended for clinical diagnosis or therapeutic use.
Need help selecting the correct product or pack size?Our team can review your application, compatibility and supply requirements.
See the configuration. Understand the workflow. Choose the right accessories.
iScope binocular microscope with EWF 10x/22 mm eyepieces, plan phase PLPHi 10/20/S40/S100x oil IOS objectives, Zernike phase contrast disc condenser with darkfield stop, rackless stage and Köhler 3 W NeoLED illumination.
Use thin, suitably prepared specimens for transmitted-light observation. Match the objective, condenser setting and contrast technique to your specimen. This configuration is selected by its exact catalogue number.
For teaching and research observations of cells, tissue sections and suitable microorganisms. Specimen preparation affects the detail you can observe.
Read the supplied objectives and eyepiece specification below. Total magnification is eyepiece magnification multiplied by objective magnification.
A camera requires a compatible optical port and adapter unless an integrated camera is explicitly listed. Binocular and trinocular heads have different camera options.
EWF 10x/22 mm eyepieces
The eyepiece magnification combines with the objective. Field number helps compare the visible area when the optical setup is otherwise equivalent.
Binocular version with Siedentopf 30° inclined tubes. Interpupillary distance 48-76 mm with diopter adjustment on both eyepieces
Viewing heads affect how you use the instrument and whether a dedicated camera port is available. A camera and adapter may need to be purchased separately.
187/230 x 140 mm rackless stage equipped with integrated 79 x 52 mm mechanical stage
Stage size determines the space for the specimen. Mechanical travel determines how far you can scan without repositioning the slide.
Coaxial coarse and fine adjustments with 200 graduations. Precision 1 μm, 0.2 mm per rotation. Total travel approximately 24 mmRack-stop for protection of slides and objectives. Friction adjustment
Fine focus helps resolve small changes in specimen height at higher magnification. Use the focusing controls and travel limits according to the manual.
Height adjustable Zernike rotating N.A. 1.25 condenser with phase annuli and darkfield stop
The condenser shapes the illumination at the specimen. Its iris needs adjustment for the selected objective and observation technique.
Diascopic intensity adjustable 3 W NeoLED Köhler illumination with Internal 100-240 V power supply (CE)iCare Sensor: The illumination of the microscope automatically switches off when the microscopist steps away from his position, saving energyCSS - Cable Storage System. The Cable Storage System of the iScope allows the user to easily insert the power cable into the back of the instrument, which enables easy storage
Check both the illumination method and its power requirements. Adjust brightness for the sample and viewing conditions.







HAYU learning illustration. It explains the workflow and is not a drawing of the supplied equipment.
| Model number | IS.1152-PLPHi |
|---|---|
| Series | iScope · Education biological microscopes |
| Level | Professional |
| Eyepieces | EWF 10x/22 mm eyepieces |
| Head | Binocular version with Siedentopf 30° inclined tubes. Interpupillary distance 48-76 mm with diopter adjustment on both eyepieces |
| Nosepiece | Revolving quintuple reversed nosepiece on ball bearings plan phase PLPHi 10x/0.25, 20x/0.40, S40x/0.65, S100x/1.25 oil immersion IOS objectives |
| Optics | All optics are anti-fungus treated and anti-reflection coated for maximum light throughput |
| Stage | 187/230 x 140 mm rackless stage equipped with integrated 79 x 52 mm mechanical stage |
| Focusing | Coaxial coarse and fine adjustments with 200 graduations. Precision 1 μm, 0.2 mm per rotation. Total travel approximately 24 mmRack-stop for protection of slides and objectives. Friction adjustment |
| Condenser | Height adjustable Zernike rotating N.A. 1.25 condenser with phase annuli and darkfield stop |
| Illumination & power | Diascopic intensity adjustable 3 W NeoLED Köhler illumination with Internal 100-240 V power supply (CE)iCare Sensor: The illumination of the microscope automatically switches off when the microscopist steps away from his position, saving energyCSS - Cable Storage System. The Cable Storage System of the iScope allows the user to easily insert the power cable into the back of the instrument, which enables easy storage |
Model specifications are taken from the supplied Euromex catalogue and linked manufacturer resources. Configurations can vary by catalogue number. HAYU can confirm current supplied components before ordering.
Videos load only after you select Play. Hosted by Vimeo.
Manufacturer tutorial for the named series or configuration. Match the supplied components to the specification above.
Open video separatelyGeneral training video. It may show different equipment.
Open video separatelyGeneral training video. It may show different equipment.
Open video separatelySupplied with power cord, 500 mA 250 V spare fuse, 5 ml immersion oil, dust cover, alignment telescope and green filter in styrofoam case
Additional cameras, stands, adapters and accessories are included only when named in this product’s supplied configuration.
Listed by the manufacturer for this series. Compatibility can depend on optical configuration, head or stand. Confirm the fit for IS.1152-PLPHi before ordering.
Tell HAYU Biomedical about your sample, required observation or measurement, and existing equipment. Include this catalogue number so we can check the configuration and compatible accessories.
Ask about this productResearch and education use only. Not intended for clinical diagnosis or therapeutic use.
Browse the education range and compare model configurations. Confirm the exact specification on the selected product page before ordering.
Open / download catalogue PDF